Phased Array probe frequency and elements: what to compare

Compare frequency, total elements, active aperture and pitch before requesting a Phased Array probe quotation. Includes a worked example and compatibility checklist.

1. Frequency: resolution and sound path

Frequency is a selection criterion, but it does not define a probe on its own. Material, sound path, geometry, detection objectives and the inspection procedure also matter.

A higher frequency can improve focusing, but it can also increase attenuation. Lower frequencies are worth evaluating for long sound paths or highly attenuative materials. Check the selection under conditions representative of the actual component. [1]

Do not choose by thickness alone.

Two components of the same thickness may require different configurations because of their material, geometry or sound path. Compare signals from a suitable reference reflector before deciding.

2. Total elements and active elements are different

A 64-element probe does not mean the instrument activates all 64 simultaneously. For example, a group of 16 elements can generate a beam and move electronically along the array, where the instrument and acquisition mode support it. [2]

When requesting a quote, distinguish the total elements in the probe from the maximum the instrument can activate for one focal law. Confirm these capabilities with the instrument manufacturer: a matching connector alone does not establish compatibility.

Request these four details separately: instrument model, active channels, addressable elements and acquisition mode. Conventional PAUT and FMC/TFM acquisition require checking their specific conditions.

3. Pitch and aperture: a worked example

Pitch is the center-to-center spacing between elements. Active aperture depends on the number of elements used, the pitch and the width of each element. The dimension perpendicular to the array is separate and should also be checked. [3]

For a regular linear array, the geometric span of the group is A = (n − 1) × p + e: n is the number of active elements, p is pitch and e is one element’s width along the array.

Hypothetical example with p = 0.6 mm and e = 0.5 mm; this is not a commercial part number:

Active elements (n)Group aperture (A)
169.5 mm
3219.1 mm
6438.3 mm

Using 16 elements of a 64-element probe keeps that group’s aperture at 9.5 mm in this example. The remaining elements allow other positions or groups, depending on the configuration. A larger aperture alone does not guarantee a better inspection.

Pitch also affects grating lobes. Evaluate it together with frequency and operating angles rather than selecting it independently. [4]

4. How to compare two options before buying

  • Keep the inspection objective consistent: material, coverage area, reflectors and procedure criteria.
  • Compare the complete configuration: probe, wedge, cable, connector and instrument.
  • Check access: available space, curvature and mechanical travel.
  • Request representative validation: coverage, signal and signal-to-noise ratio with the proposed configuration.

Do not replace a part just because its MHz and element count match: check dimensions, pitch and accessories too. If you already use a probe, send its part number or a legible photograph of its label.

5. Information for a quotation request

  • Instrument brand, model and inspection mode.
  • Material, thickness, geometry and application.
  • Current probe part number, if available.
  • Frequency, elements, pitch and dimensions required or to be evaluated.
  • Wedge: required part number, angle and curvature.
  • Cable: length, connection and access requirements.
  • Delivery country and required quantity.

We can review your request for Vermon Phased Array probes and the necessary accessories. The final selection must suit your instrument and procedure.

Frequently asked questions

Do more elements always mean better results?

No. Check how many your instrument can use, the active aperture, access and required coverage. Compare the complete configuration and validate the result for your application.

General probe selection guide ↗

Technical references

  1. Evident — Beam Shaping
  2. Evident — Phased Array Instrument Specifications
  3. Evident — Phased Array Probe Selection Summary
  4. Evident — Grating Lobes and Side Lobes

Request a Vermon probe quote

Compare frequency, total elements, active aperture and pitch before requesting a Phased Array probe quotation. Includes a worked example and compatibility checklist.

WhatsApp · +1 954 880 4033 ↗