1. Identify both cable ends
An ultrasonic testing cable should be described from instrument to probe. “BNC cable” identifies only part of the request if the other end remains unspecified. List the instrument connection and transducer connection separately when requesting a quotation.
Eddyfi's catalog includes BNC, Microdot, LEMO 00, LEMO 1 and MCX connections, along with dual configurations. These names help locate a family; the full part number identifies the requested assembly. [1]
Send a front and side photograph of each connector. If you still have the previous cable, include its label and a photograph of both ends together. Do not force a connection to check whether it fits.
2. What to check for BNC, Microdot, LEMO and MCX
| Listed name | Detail to confirm |
|---|---|
| BNC | Electrical variant, contact type and connector at the opposite end. |
| Microdot / MD | Exact designation, thread and probe part number. |
| LEMO 00 | Full series designation, contact and cable configuration. |
| LEMO 1 | Exact part number; do not substitute LEMO 00 without verification. |
| MCX | Part number, contact type and straight or angled exit. |
MCX uses a snap-on coupling, and variants with different impedances exist. [2] LEMO describes its coaxial 00 series as using push-pull latching. [3] The coupling mechanism helps identify a family, but does not by itself establish electrical compatibility.
When ordering a replacement, provide the part number of the cable that worked with the instrument. A similar appearance does not replace a specification check.
3. Length, exit and operating conditions
Measure the actual route between instrument and probe, including movement during scanning. Specify length in meters or feet and confirm how the supplier measures the assembly. State whether a straight or 90° exit is required and at which end.
Describe the application: manual inspection, scanner use, repeated flexing, abrasion, water or proximity to a hot surface. Request confirmation that the jacket and assembly suit those conditions; do not infer water or temperature resistance from appearance.
If you change the length or add an extension, request a review of the full assembly and any performance checks required before using it for inspection.
4. Single, dual and Phased Array cables
For a dual-element or TOFD request, specify every connection and its function. Clarify whether you need two individual cables, a dual assembly or a partial replacement. A photograph of the current arrangement helps identify the required part.
For Vermon Phased Array, send the array and instrument part numbers. The manufacturer offers different connector options and asks users to select the configuration appropriate for the instrument. [4] A PAUT cable or adapter request must be reviewed as a specific configuration.
Do not treat a conventional UT coaxial cable and a multichannel PAUT assembly as interchangeable. Also clarify whether the cable is integrated into the probe or has a detachable connection before requesting a cable-only replacement.
5. Adapters: describe the complete connection
If you use an adapter, include its part number in the inquiry and show where it is installed. Write out the complete sequence: instrument, adapter, cable and probe. Ask the quotation to distinguish included components from those you will retain.
An adapter that enables a physical connection does not by itself demonstrate that the combination is suitable for inspection. Request a review of connectors and assembly specifications; avoid chaining components together without a confirmed configuration.
To organize spares, keep a record for each instrument with the cable part number, length, photograph and available quantity. An urgent purchase then need not depend solely on recognizing a connector by sight.
6. Ready-to-use quotation checklist
- Instrument: brand and model.
- Probe: brand, part number and label photograph.
- Instrument-side connector: part number and photograph.
- Probe-side connector: part number and photograph.
- Length and exit: straight or angled at each end.
- Configuration: single cable, dual cable, extension or adapter.
- Operating conditions and required quantity.
- Delivery city, country and required date.
Example inquiry: “I need two cables for my current flaw detector and probe. Part numbers and photographs of both connectors are attached. I require 2 m and an angled exit at the probe end. Please confirm the configuration and lead time.”
UT Probes LATAM welcomes requests for ultrasonic testing cables and accessories. Compatibility, availability and lead time are confirmed before finalizing the quotation. Request cables alone or include them with probes and wedges.
Frequently asked questions
Is asking for a BNC cable enough?
No. Specify the connector at the other end, length, instrument and probe part numbers. The electrical specifications of the assembly also need confirmation.
Are LEMO 00 and LEMO 1 the same?
Do not treat them as a single part designation. Send the complete connector designation and photographs; LEMO alone does not identify the required connection.
Can I request just the cable?
Yes. You can request a quotation for the cable or adapters alone. Include instrument and probe details so the combination can be reviewed.